Another Example of How Important Wire is to Wireless

A house built on a shaky foundation cannot endure. And a WLAN built on a shaky wiring foundation likewise cannot endure, I tellya. My friends, is your foundation shaky? Is it? CHECK YOUR FOUNDATION NOW. (I happen to sell foundation-strengthening herbal supplements on the side, if you need that sort of thing…)

I’ve long been a proponent of recognizing installed UTP as a vital component in the networking ecosystem. Too many people take Layer 1 for granted, and forgivable sins of of our 10 Mbps and Fast Ethernet pasts won’t fly in a Gig world. Toolmakers like Fluke Networks sell cable certification testers that take the guesswork out of whether a given cable run can be relied on to perform as expected. Don’t use one of these testers at time of cable installation, and you are only assuming you have a good station cable.

I just had an interesting situation come up that I helped a very skilled field tech with. He was working in several different small buildings, each serviced by a Cisco Catalyst Switch and a handful of 3802 802.11ac access points. The switches and cable had been in place for years, and the APs for many months, all with no issues whatsoever.

Then, we changed out the old 3560X switches for shiny new 3650s (curse you Cisco for your bizarre fascination with part numbers so close together), and suddenly some APs weren’t working any more. Between us, we checked all switch settings, POST reports, CDP tables, logs, etc- everything you can dream up on the switch. We put the APs that weren’t working back on the old switches, and they came right up. Hmmm… thoughts turned to PoE/code bugs, but then I went a-Googlin’ before consulting TAC.

I found this document that put me on the path to righteousness. Though we weren’t having “PoE Imax Errors”, a couple of nuggets jumped out at me about our new switches.

PoE Imax

Holy guacamole- We got us a situation! But wait… THERE’S MORE!

PoE Imax2

Shazam! Which, of course, translates in Esperanto to “maybe your cable is actually kind of iffy, and all the CDP stuff that happens at the milliwatt level before PoE gets delivered worked OK with your old switch but not with the new one that has the enhanced PoE controller”.

If you don’t know that the newer switch does PoE differently, you might wrongly assume that your cabling is “good” because the APs worked on it when those APs used the old switches connected to that wiring. By now, you can probably guess where I’m headed…

Our tech tested the cabling on the new-switch-problem APs and in each case found that they needed help to work with the new switch. He re-terminated and tested each, with the APs then coming up with no issues. I have no doubt that this cable was certified 10-12 years ago, but in that time a lot can happen to either end of those cables depending on the environments where they are used.

Live and learn!

 

 

5 thoughts on “Another Example of How Important Wire is to Wireless

  1. Dermot Allen

    thanks for writing this blog. We always assume it must be the others guys issue…and most times it is…but everyone once in awhile we find the issue on our side. It is always good to keep in mind the old saying KISS or in this case start at layer 1.

    Thanks again Lee ….I always enjoy and learn from your posts

    Reply
  2. Stefano

    When I have AP connectivity issues that aren’t explained by the usual troubleshooting steps, my go to commands for Cisco switches are:

    test cable-diagnostics tdr interface
    ! Wait a few seconds….
    show cable-diagnostics tdr interface

    Does the job every time. I then send the info to the cablers to repair.

    Reply

Tell me what YOU think.

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google+ photo

You are commenting using your Google+ account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s